DOCUMENT 2090 RE-INITIALIZATION PROCEDURE Step #1 Go into management access and run PROGRAM #10, PROGRAM #20 and PROGRAM #32. If you have programmed Automatic Multi Reports print out a Multi Report #7 for a copy of how they are set up. These printouts clearly show any on site programming that was done and can be referenced when re-programming the system. Step #2 Run all reports that you need on the call records stored in the memory of the unit. *** THIS IS VERY IMPORTANT *** because the call records will be erased after the re-initialization. Step #3 Go into management access, press PROGRAM #248 and ENTER. You must press the red button on the back of the system to reset the INN-FORM/PLUS system. Program #248 removes any glitches in memory and tells the unit to initialize and reset to factory defaults The system will print out a program #10 and a re-initialization message. Step #4 Re-program any on-site parameters (ie grace periods, surcharges, mark-ups, etc.). The system is now ready to process call record information.