DOCUMENT #8040 INNSURE CABLES PROBLEM VOLTS NORMAL VOLTS DISCONNECTED SMDR IN DISCONNECTED: PIN 4,5 NEGATIVE NO VOLTAGES The on hook/off hook looks normal but as you hang up the timers will not freeze insteadly like it does if it's hooked up properly. You will not get SMDR IN/OUT on the display in the window at the bottom of the screen. VOLTS NORMAL VOLTS BACKWARDS SMDR IN CONNECTED BACKWARDS: PINS 4,5 NEGATIVE PINS 2,20 NEGATIVE PINS 3,6 POSITIVE The OFF/HOOK CONNECT timer doesn't freeze the timer right after the call has disconnected. No SMDR IN/OUT displayed. VOLTS NORMAL VOLTS BACKWARDS SMDR OUT CONNECTED BACKWARDS: PINS 3,20 NEGATIVE PINS 4,5 NEAGATIVE 6 POSITIVE Everything acts normal. SMDR IN/OUT is displayed in the bottom window as normal. The output wasn't getting SMDR signal to the call accounting. VOLTS NORMAL VOLTS DISCONNECTED SMDR OUT DISCONNECTED: PINS 3,20 NEGATIVE NO VOLTAGES This has the same syntoms as the problem: SMDR OUT BACKWARDS. It gets no SMDR signal to the call accounting. VOLTS NORMAL VOLTS DISCONNECTED IDE CABLE DISCONNECTED: PIN 4,5 NEGATIVE NO VOLTAGES The ON HOOK/OFF HOOK looks normal but as you hang up the timers will not freeze insteadly right after the call is hung up. In proper working conditions it does freeze. You will not get SMDR IN/OUT on the display in the window at the bottom of the screen. VOLTS NORMAL VOLTS BACKWARDS IDE CABLE CONNECTED BACKWARDS:PIN 4,5 NEGATIVE SMDR IN 4,5 NEGATIVE (ON THE INNSURE CARD) 3,6,8 POSITIVE SMDR OUT 3,20 NEGATIVE (ON THE IDE CARD) PIN 4,5 NEGATIVE SMDR IN 4,5 NEGATIVE 3,6 POSITIVE SMDR OUT 3,20 NEGATIVE This gets no SMDR IN/OUT and the off hook counter doesn't freeze the numbers insteadly. CO LINES DISCONNECTED: The OFF HOOK/ON HOOK on the display will be dead. CO LINES CONNECTED BACKWARDS: No dial tone/ or activity on the screen. (ON THE INNSURE CARD) PBX DISCONNECTED: No dial tone/ or activity on the screen. PBX BACKWARDS: No dial tone/ or activity on the screen.